Return to Frequency Converter / Voltage Converters Product Page
|
VOLTAGE
& FREQUENCY CONVERTER SELECTION GUIDE |
||||||
|
Model Family |
SG © (Single
Output) |
SG © (Dual
Output) |
SVR © (Single &
Dual) |
ED-A © (Single
Output) |
(Single
Output) |
(Single
Output) |
|
Features |
||||||
|
Sizes Available (Tower Enclosure) |
2kVA, 3kVA, 5kVA & 6kVA |
1kVA, 1.5kVA, 2kVA, 2.4kVA,
3kVA, 4kVA & 5kVA |
1kVA, 1.5kVA, 2kVA &
2.4kVA |
1kVA, 1.5kVA, 2kVA, 2.4kVA |
||
|
Sizes Available (Rackmount Enclosure) |
N/A |
N/A |
N/A |
N/A |
||
|
Rackmount Mounting Slides Available? |
Rackmount Models Only |
N/A |
YES |
NO |
NO |
NO |
|
Input/Output Voltage(s) |
800VA-3kVA Models -1 Models 100-120Vac -2 Models 200-240Vac 5-6kVA -X1T, X2T & X2TC Input:
-X1T = 120Vac -X2T = 208-240Vac Output
1: -X1T & X2T 208-240Vac 5-6kVA -2T & -2TC Input: 208-240Vac Output: 208-240Vac |
2-3kVA Models Input 208-240Vac Output 1: 120Vac Output 2: 208-240Vac 5-6kVA –TX, -TXC Models Input: 208-240Vac Output 1: 120Vac Output 2: 208-240Vac |
1-3kVA -1 Models 100-120Vac -2 Models 200-240Vac 4-6kVA -1 Input: 120Vac Output 1: 208-240Vac Output 2: 120Vac -2 Input: 208-240Vac Output 1: 208-240Vac Output 2: 120Vac |
Models 120Vac |
1-2kVAModels Input: 100Vac or
220-240Vac Output: 100Vac or
220-240Vac |
Models 100-120Vac |
|
Output Voltage Regulation |
±2% |
±3% |
||||
|
Output Waveform |
True Sinewave |
|||||
|
Input/Output Phase |
Single/Single |
Single/Single |
Single/Single |
Single/Single |
Single/Single |
Single/Single |
|
Input Power Factor Correction |
YES |
YES |
YES |
NO |
NO |
YES (low current distortion) |
|
Galvanic Isolation |
SG 5-6kVA Input of -X1T, -X2T & -2XTC Models Only |
2kVA: Outputs 1 & 2 3, 5 & 6kVA: Output 1 |
NO |
NO |
NO |
NO |
|
True On-line Design |
YES |
YES |
YES |
YES |
YES |
YES |
|
International Frequency Conversion (50 & 60Hz) |
YES |
YES |
YES |
YES |
YES |
YES |
|
Military & Aircraft 120Vac, 400Hz Conversion |
NO |
NO |
NO |
Input or Output |
1-2kVA Input or Output 3-4kVA Input Only |
Output Only |
|
Military Grade Designation |
COTS |
COTS |
COTS |
COTS |
COTS |
COTS |
|
On GSA? |
NO |
NO |
NO |
YES |
YES |
PENDING |
|
UPS |
YES |
YES |
NO |
External Option |
External Option |
External Option |
|
Available Without Batteries? |
NO |
Use SVR |
Standard |
Standard |
Standard |
Standard |
|
Line Cord, Plug & Receptacles Standard on Unit |
YES |
YES |
YES |
YES |
YES: 1-2kVA Models NO: 3-4kVA Models |
YES |
|
Hardwire Configuration Available |
5 & 6kVA Only |
NO |
NO |
NO |
3-4kVA Models Only |
|
|
Microprocessor Controlled |
YES |
YES |
YES |
NO |
NO |
NO |
|
Dry Contact Closure Interface |
OPTIONAL |
OPTIONAL |
OPTIONAL |
YES |
YES |
YES |
|
True RS-232 Interface |
YES |
YES |
YES |
NO |
NO |
NO |
|
Computer Shutdown & Management Software |
YES Upsilon |
YES Upsilon |
YES Upsilon |
NO |
NO |
NO |
|
SNMP/HTTP Web Interface |
OPTIONAL |
OPTIONAL |
OPTIONAL |
NO |
NO |
NO |
©1999-2008
Falcon® Electric, Inc. All rights reserved throughout the world. Falcon and the Falcon
Electric logo are registered trademarks of Falcon Electric, Inc. All other brand
names and trademarks are the property of their respective owners. The information
and specifications stated on this website are subject to change without notice.