| _____________________ ____About Us _____Products_____ Service & Support _____Downloads____ Contact Us |
GSA/COTS SELECTION GUIDE
|
Model Family |
ED-A (Single Output) |
ED-1 (Single Output) |
ED-LC (Single Output) |
EDRM (Single Output) |
EDRM-3Ø Input 1Ø Output (Single Output) |
|
Features |
|||||
|
Models Available on GSA Schedule |
GSA 1-2kVA |
GSA 1-2kVA |
GSA 1-2kVA |
GSA 1-2kVA |
GSA 1.5-2.4kVA |
|
Sizes Available
|
1kVA, 1.5kVA, 2kVA, 2.4kVA, 3kVA, 4kVA & 5kVA |
1kVA, 1.5kVA, 2kVA, 2.4kVA |
1kVA, 1.5kVA, 2kVA, 2.4kVA |
1kVA, 1.5kVA, 2kVA, 2.4kVA, 3kVA, 4kVA, & 5kVA |
1.5kVA, 2kVA, 2.4kVA, 3kVA, 4kVA & 5kVA |
|
Product Functions |
Voltage Regulator & Frequency Converter |
UPS, Voltage Regulator & Frequency Converter |
Voltage Regulator, Voltage & Frequency Converter |
UPS, Voltage Regulator & Frequency Converter |
Phase Converter, Frequency Converter, Voltage Regulator, UPS |
|
Form Factor |
Mini-tower |
Mini-tower |
Mini-tower |
19” Rackmount |
1.5-2.4kVA 2U 19” Rackmount 3-5kVA unit 4U 19” Rackmount Batteries 2U 19” Rackmount |
|
(19” Rackmount Conversion Kit?) |
N/A |
N/A |
N/A |
Standard |
Standard |
|
Rackmount Mounting Slides Available? |
N/A |
N/A |
N/A |
YES |
YES |
|
Input/Output Voltage(s)1 |
120Vac |
120Vac |
AC Input: 100Vac or 220-240Vac Output: 100Vac or 220-240Vac |
AC Input: 120Vac Output: 120Vac |
AC Input: 200/115 3Ø Wye Output: 120Vac, 1Ø |
|
Typical Output Voltage Regulation |
±3% |
±3% |
±3% |
±3% |
±3% |
|
Input/Output Phase |
1Ø /1Ø |
3Ø /1Ø |
|||
|
Auto-Transformer Option Available? |
NO |
NO |
Standard |
NO |
NO |
|
MS Connectors Available? |
Option |
Option |
Option |
YES |
YES |
|
Galvanic Isolation Option Available? |
NO |
NO |
NO |
NO |
1.5-2.4kVA Only |
|
True Double Conversion On-line Design? |
YES |
||||
|
Frequency Conversion? (50 & 60Hz) |
YES |
YES |
YES |
YES |
YES |
|
Military & Aircraft 120Vac, 400Hz Conversion |
Input and/or Output |
Input and/or Output |
Input and/or Output |
Input and/or Output |
Input: 400Hz 3Ø Output: 50, 60 or 400Hz 1Ø Input: 45-400Hz 3Ø Output: 50, 60 or 400Hz 1Ø |
|
Input Power Factor Correction |
Option |
NO |
NO |
Option |
NO >0.9pf |
|
UPS Battery Backup Provided? |
NO |
Standard |
Option |
YES |
YES |
|
Available Without Batteries? |
Standard |
NO |
Standard |
YES |
YES |
|
Optional Hawker High Temperature Batteries? |
NO |
NO |
NO |
Option |
Option |
|
Operational Temperature Range |
-20ºC - +50ºC |
||||
|
Ruggedized? |
NO |
NO |
NO |
YES |
YES |
|
Line Cord, Plug & Receptacles Standard |
YES |
YES |
YES |
YES |
YES |
|
Hardwire Configuration Available |
NO |
NO |
NO |
NO |
NO |
|
Microprocessor Controlled |
NO |
NO |
NO |
NO |
NO |
|
Dry Contact Closure Interface |
YES |
YES |
YES |
YES |
YES |
|
True RS-232 Interface |
NO |
NO |
NO |
NO |
NO |
|
Computer Shutdown & Management Software |
Shutdown Only |
Shutdown Only |
Shutdown Only |
Shutdown Only |
Shutdown Only |
|
SNMP/HTTP Web Interface |
NO |
NO |
NO |
NO |
NO |
1. Only one transformer per unit. If the output voltage desired is 220-240Vac, the output voltage must be 120Vac. If the input voltage is 120Vac, the output can be either Vac or 200-240Vac.
|
©1999-2010
Falcon® Electric, Inc. All rights reserved throughout the world. Falcon and the Falcon
Electric logo are registered trademarks of Falcon Electric, Inc. All other brand
names and trademarks are the property of their respective owners. The information