FALCON ON-LINE
UPS SELECTION GUIDE
|
|||||||
Model Family
|
(Single Output)
(No Isolation)
|
(Single Output)
(No Isolation)
|
(Dual Output)
(With Isolation)
|
(Single & Dual Output)
(With Isolation) |
(Single Output)
(No Isolation)
|
(Single Output)
(No Isolation)
|
(Single Output)
(With Isolation)
|
Features
|
|||||||
Sizes Available
(Tower)
|
1.5kVA 2.2kVA & 3kVA
Standard
|
800VA, 1kVA, 1.5kVA,
2kVA, 3kVA, 5kVA & 6kVA
|
2kVA, 3kVA, 5kVA & 6kVA
|
3kVA to 40kVA
3, 4, 5, 6, 8 & 10kVA Units
|
1kVA, 1.5kVA, 2kVA &
2.4kVA
|
N/A
|
500VA
|
Sizes Available
(Rackmount Enclosure)
|
1.5kVA, (1 2U Rackmount)
2.2kVA & 3kVA
(2 2U Rackmount)
|
1kVA, (1 2U Rackmount)
2kVA & 3kVA
(2 2U Rackmount)
|
N/A
|
Available early 2009
|
N/A
|
1kVA, 1.5kVA, 2kVA ,
2.4kVA, 3kVA, 4kVA & 5kVA
|
Flat Table Top
|
Rackmount Mounting Slides Available?
|
YES
|
Rackmount Models Only
|
NO
|
NO
|
NO
|
YES
|
NO
|
Product Functions
|
UPS, Voltage Regulator,
Power Factor Corrector
|
UPS, Voltage Regulator,
Power Factor Corrector
|
UPS, Voltage Regulator,
Power Factor Corrector
|
UPS, Voltage Regulator,
Power Factor Corrector
|
UPS, Voltage Regulator
|
UPS, Voltage Regulator
|
UPS, Voltage Regulator
|
Input/Output Voltage(s)
|
-1 Models
Input/Output
120Vac
_-2 Models
Input/Output
200 or 220 or 230 or
240Vac
|
800VA-3kVA Models
-1 Models
Input/Output
100-120Vac
-2 Models
Input/Output
200-240Vac
5-6kVA
-X1T, X2T & X2TC
Input:
-X1T = 120Vac
-X2T
= 208-240Vac
Output
1: -X1T & X2T
208-240Vac
5-6kVA
-2T & -2TC
Input:
208-240Vac
Output:
208-240Vac
|
2-3kVA Models
Input 208-240Vac
Output 1: 120Vac
Output 2: 208-240Vac
5-6kVA -TX &
-TXC Models
Input 208-240Vac
Output 1: 120Vac
Output 2: 208-240Vac
|
-T Models
Input: 208-240Vac,
Hardwire
Output : 208-240Vac,
Hardwire
No input/output isolation
-TX Models
Input: 208-240Vac,
Hardwire
Output 1: Isolated 120Vac,
Hardwire
Output 2: 208-240Vac,
Hardwire
-TXI Models
Input: 208-240Vac,
Hardwire
Output: 3 wire plus ground
120/240Vac, Hardwire
|
-1 Models
Input/Output
120Vac
|
-1 Models
Input/Output
120Vac
|
-1 Models
Input/Output
120Vac
|
Input/Output Phase
|
Single/Single
|
||||||
Standard Input/Output Frequency
|
50/60Hz
Auto Select
|
50/60 Auto Select
(user programmable)
|
50/60/400Hz
Set at Factory
|
50/60/400Hz
Set at Factory
|
50/60Hz
Set at Factory
|
||
International Frequency Conversion Fixed 50/60Hz Option?
|
YES
|
YES
(Derate output 25%)
|
YES
|
||||
True On-Line UPS
|
YES
|
||||||
55°C (131°F) High Temp Operation?
|
YES
|
NO
|
NO
|
NO
|
YES
|
YES
|
NO
|
Input Power Factor Correction?
|
YES
|
YES
|
NO
|
NO
|
NO
|
NO
|
|
Output Voltage Regulation?
|
±2% Typical (See
datasheet)
|
±2%
|
±3%
|
||||
Output Waveform?
|
True Sinewave
|
||||||
Output Load Segment Control?
|
YES
|
NO
|
NO
|
NO
|
NO
|
NO
|
NO
|
Can UPS Units be Connected in Parallel? (up to 4 units)?
|
NO
|
NO
|
YES
|
NO
|
NO
|
NO
|
|
Can UPS Units be Configured for N+1 Redundant Operation (up to 4 units)?
|
NO
|
NO
|
YES
|
NO
|
NO
|
NO
|
|
User-Replaceable Batteries?
|
YES
|
NO
|
NO
|
YES
|
NO
|
NO
|
NO
|
Hot-swappable Batteries?
|
YES
|
2
& 3k Rackmount Models Only
|
NO
|
YES
|
NO
|
NO
|
NO
|
|
YES
|
NO
|
YES
|
NO
|
NO
|
NO
|
|
Optional Extended
|
YES
|
YES
|
YES
|
YES
|
YES
|
YES
|
|
Input Galvanic Isolation?
|
NO
|
-X1T, -X2T & -2XTC
5 & 6kVA
Models Only
|
-X2T 2 & 3kVA Models
(Single Output Only)
|
NO
|
NO
|
NO
|
NO
|
Output Galvanic Isolation?
|
NO
|
2kVA:
Output 1 & 2
3, 5 & 6kVA:
Output 1 only
|
-TXI Models
|
NO
|
NO
|
YES
(Internal high frequency galvanic isolation)
|
|
Line Cord, Plug & Receptacles Standard on Unit?
|
YES
|
NO
|
YES
|
||||
Special Output Receptacle Configurations Available Upon Request?
|
YES
|
||||||
Hardwire Configuration Available?
|
NO
|
Specified 2, 3, 5 &
6kVA Models
All other models contact
factory
|
NO
|
Standard
|
NO
|
YES
|
NO
|
External No-Break Maintenance Bypass Switch Available?
|
YES
|
NO
|
NO
|
NO
|
NO
|
NO
|
|
Microprocessor Controlled?
|
YES
(dual)
|
YES
(single)
|
YES
|
DSP Microprocessor
|
NO
|
NO
|
NO
|
Dry Contact Closure Interface?
|
OPTIONAL
|
OPTIONAL
|
YES
|
YES
|
YES
|
YES
|
|
True RS-232 Interface?
|
YES
|
YES
|
NO
|
NO
|
NO
|
NO
|
|
USB Interface?
|
YES
|
Optional Cable
|
NO
|
OPTIONAL
|
NO
|
NO
|
NO
|
Computer Shutdown & Management Software?
|
YES
|
YES
|
YES
|
YES
|
YES
|
YES
|
|
SNMP/HTTP Web Interface?
|
OPTIONAL
|
OPTIONAL
|
YES
|
NO
|
NO
|
NO
|
|
Model
Family
|
(Single Output)
(No Isolation)
|
(Single Output)
No Isolation
|
(Dual Output)
(With Isolation)
|
(Single & Dual Output)
(With Isolation) |
(Single Output)
(No Isolation)
|
(Single Output)
(No Isolation)
|
(Single Output)
(With Isolation)
|
|
©1999-2010
Falcon® Electric, Inc. All rights reserved throughout the world. Falcon and the Falcon
Electric logo are registered trademarks of Falcon Electric, Inc. All other brand
names and trademarks are the property of their respective owners. The information