UPS
Selection Guide
_
UPS Power Problem Comparison Chart |
|||
|
Off-line |
Line-interactive |
True On-line |
Provides battery backup with no output interruption? |
no |
no |
☑ |
Can the UPS be started on battery without being plugged into a utility source? (portable applications) |
✓ most will not |
✓ some will |
✓ |
Does the UPS continue to operate when the batteries completely fail? |
Most do not |
Some do not |
✓ Most will |
Provides output AC voltage regulation while on utility & battery? |
none |
✓ +12% typ. |
✓ +2% typ. |
Provides output frequency regulation while on utility and battery? |
On battery only |
On battery only |
✓ |
Can the UPS be operated from a 120Vac, 400Hz source? |
no |
no |
✓ A few can |
Does the UPS provide input power factor correction? |
no |
no |
✓ Many models available |
Does the UPS provide input to output isolation? |
no |
no |
✓ Some models |
Supports the addition of a Simple Network Management Protocol, SNMP/HTTP interface board? |
✓ no |
✓ most |
✓ most |
Can the UPS be operated below 32ºF and above 90ºF ? |
no |
no |
✓ Some models available |
Does the UPS protect equipment against a direct lightning strike?
|
no |
no |
No |
Should the UPS be used with other microprocessor or microcontroller based applications? |
✓ usage should be reviewed closely |
✓ |
✓ |
Should the UPS be used with large motor loads? |
no |
✓ Sinewave output models only if sized properly |
✓ If sized properly |
Should the UPS be used with laser printers?
|
no |
✓ If sized properly |
✓ If sized properly |
Can the UPS be used as a international frequency converter? |
no |
no |
✓ |
Should the UPS be used with generator sources? |
no |
no |
✓ |
Should the UPS be used to power equipment that is sensitive to input voltage changes? |
no |
no |
✓ |
Should the UPS be used to power HID lighting systems? |
no |
no |
✓ If sized properly |
Should the UPS be used on security or telephone systems requiring backup time of greater than an hour? |
no |
no |
✓ |
Should the UPS be used to power emergency lighting ? |
no |
no |
✓ |
Should the UPS be used to power radio frequency based communications equipment? |
no |
no |
✓ |
Can the UPS be used for portable emergency backup power where utility in not present? |
no |
✓ Must have sinewave output and DC start capability |
✓ Must have DC start capability |
_
_
_
_
_
_
©1999-2013
Falcon® Electric, Inc. All rights reserved throughout the world. Falcon and the Falcon
Electric logo are registered trademarks of Falcon Electric, Inc. All other brand
names and trademarks are the property of their respective owners. The information
and specifications stated on this website are subject to change without notice.
Legal & Private Policy | Contact Us
_